Basic settings

General configurations of the application can be adjusted via the menu article Basic settings.


Field Description
Language Application display language
Inventory number changeable Switch enables the inventory number of an article to be changed under article data
Automatic issue after maintenance Articles that belong to a fire department are automatically returned to the fire department after maintenance
Insert standard suppliers Creates a pool of existing suppliers under producer/suppliers
Automatically close repair during scan in the check If there is a repair for the article, this is automatically closed during the scan, in a check
Designation of the licensee in reports Designation when printing out the reports, as licensee, is given
(In the event that the licensee is not the same as the institution of the test center)
Delete the discarded hose completely After a discard, the switch removes all data that was stored for the article completely from the database
(Recovery is no longer possible)

After Save, the application is automatically reopened and all changes are applied.

Default values

Article-specific standard values can be defined via the menu article Default values.

Field Description
Inspection pressure Specifies the Inspection pressure of newly created articles
Inspection duration Specifies the check time of newly created articles
Hose Thickness Specifies the hose thickness of newly created articles
Year of production Specifies the year of manufacture, which should be stored as standard for the articles
Offset X days are added to the acceptance date, as the date for the pressure test
Hose color is the distinguishing criterion Allows the articles to automatically transfer the specified color when creating article groups
Pool hose standard Newly created articles have the switch Is pool hose automatically set
Low pressure Specifies the Low pressure of newly created articles
Low pressure duration Specifies the Low pressure duration of newly created articles

Barcode

Article-specific standard values can be defined via the menu article Barcode.

Field Description
Minimum length Indicates the minimum length of the barcode
Longer of the check digit Enables the truncation of unwanted check digits at the end of a barcode
(usually configuration of your own barcode scanner)
Prefer barcode as inventory number The switch attempts to use the scanned barcode as an inventory number when creating a new article. If the inventory number already exists, the next higher inventory number is selected

Mobile device

Connection settings for the programmable logic controller can be changed via the menu article Mobile device.

Field Description
Is a network device (Android, Dolphin) Indicates whether the synchronization with the PDA is carried out via the network
(The MC 55 uses the MobileDeviceCenter from Microsoft, which is synchronized via a USB connection)
Show dialog on device before sync If the sync is triggered from the application, a dialog for the sync request should be displayed on the PDA
Generally, the sync should be triggered via the PDA
Local IP address Specifies the IP address of the system via which the mobile synchronization is to be carried out
(Default 192.168.2.2)
Local receiving port Specifies the port via which the mobile synchronization should be carried out
(Default 12102)
MC55 - Fields For information only (obsolete)

PLC

Connection settings to the programmable logic controller can be changed via the PLC menu article.

Field Description
IP address Indicates via which network address the PLC can be reached
Send port Indicates via which port the application should receive the message from the PLC
Receive port Indicates via which port the application receives the message from the PLC